HI-POTTER FOR ION PUMPS

 


When ion pumps develop field emission leakage currents due to build up of deposits with microscopically small, sharp points, the leakage current can be reduced or eliminated by the technique known as “hi-potting”.  This involves application of high voltage, typically 10-15 KV, either DC or AC, to the ion pump high voltage feedthrough.

One supplier of equipment for hi-potting units is:

 HiPotronics

http://www.hipotronics.com/

845-279-8091, 800-727-HIPO, FAX 845-279-2467

One model which we use is:
DC Insulation Tester
Model 220, Type AS11-582-3
(0-20KV, 15MA)